California Environmental Engineering
Environmental Testing Laboratory
3231 S. Standard Ave
Santa Ana, CA 92705
(714) 545-9822 Fax: (714) 545-7667
February 18, 1997
SV Technologies
Escondido, CA
To Whom it may concern,
California Environmental Engineering an EPA recognized and C.A.R.B. licensed emission facility tested the SV Technologies device. The device was tested on a 1974 VW Beetle. The tests conducted were CVS 78 FTP cold start tests as described in the CFR Title 40 Part 86. The test results are as follows:
HC
CO
NOX
CO2
FE
Baseline
9.599
62.032
1.760
268.1
22.4
W/Device
7.407
28.711
1.939
315.9
23.1
% Change
- 22.8 %
- 53.7 %
+ 10 %
+ 17.8
+ 3 %
These test results are very good as compared to other similar devices. If you have any questions, please call Larry Swiencki at (714) 545-9822. Thank you.